Services Available |
---|
The SDM-INT8 outputs timing data to a Campbell Scientific datalogger. The datalogger can process the timing data to calculate RPM, duty cycle, velocity, crank angle, etc.
The SDM-INT8 has eight channels that are individually programmed to record the timing of input voltage transitions (events). It uses this information to output:
The data logger enables individual modules through an addressing scheme; up to 15 SDM-INT8s can be connected to one data logger. After a module is enabled, it operates independently of the data logger until additional commands are received or results are transmitted.
Operating Voltage | 9.6 to 16 Vdc |
Current Drain |
|
Maximum Timing Measurement | 16.7 s |
Resolution | ±1 µs |
Operating Temperature | -25° to +50°C |
Dimensions | 0.3 x 12.7 x 2.5 cm (8 x 5 x 1 in.) |
Weight | 0.82 kg (1.8 lb) |
High-Level Voltage Input Pulses |
|
Minimum Pulse Width | 2 µs |
Maximum Frequency (32-bit values) |
|
Maximum Frequency (16-bit values) |
|
Low-Level AC Voltage Input |
|
AC Voltage |
|
Input Hysteresis | 11 mV |
Minimum Frequency | 1 Hz |
Maximum Frequency |
|
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.
Product | Compatible | Note |
---|---|---|
21X (retired) | ||
CR10 (retired) | ||
CR1000 (retired) | ||
CR10X (retired) | ||
CR200X (retired) | ||
CR211X (retired) | ||
CR216X (retired) | ||
CR23X (retired) | ||
CR3000 (retired) | SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
CR500 (retired) | ||
CR5000 (retired) | SDMs are connected to the ports labeled SDM-C1, SDM-C2, and SDM-C3. | |
CR510 (retired) | ||
CR6 | ||
CR800 (retired) | ||
CR850 (retired) | ||
CR850 (retired) | ||
CR9000 (retired) | SDMs connect to ports provided on the CR9080 PAM module. | |
CR9000X (retired) | SDMs connect to ports provided on the CR9032 CPU module. |
Product | Compatible | Note |
---|---|---|
ENC10/12R | ||
ENC16/18 | ||
GRANITE 10 | ||
GRANITE6 | ||
GRANITE 9 |
The SDMINT8 instruction controls the SDM-INT8 operation in CRBasic. Instruction 101 controls the SDM-INT8 operation in Edlog.
The SDM-INT8 draws 20 mA. In most applications, the data logger’s sealed rechargeable power supply can be used. The data logger’s alkaline power supply has sufficient capacity to operate the SDM-INT8 during short-term installations only.
The SDM-INT8 should be housed in an environmental enclosure. A bracket is shipped with the SDM-INT8 for mounting it to an enclosure backplate.
We've updated our privacy policy. Learn More