Limited Availability ›
This product has limited availability. Some accessories, replacement parts, or services may still be available when it is no longer available.
SC12R-6 Robust CS I/O Cable, 6 ft

Overview

The SC12R-6 connects two or more 9-pin peripherals to the CS I/O port of a Campbell Scientific datalogger. The SC12R-6 may be "daisy-chained" to connect one additional peripheral with each additional cable.

This cable is similar to the SC12, but it has a 6 ft length between connectors instead of a 2 ft length.


Read More

Benefits and Features

  • Provides one 9-pin pin (male) connector and two 9-pin socket (female) connectors
  • "Robust" cable withstands environmental conditions better than ribbon cables

Images


Detailed Description

The SC12R-6 cable is similar to the SC12, but has a 6-ft length between connectors instead of a 2 ft length. This cable has one 9-pin pin (male) connector that attaches to the data logger's CS I/O port and two 9-pin socket (female) connectors that can attach to peripherals with a 9-pin RS-232 port. Additional peripherals can be connected by attaching one of the two socket (female) connectors with the pin (male) connector of an additional SC12R-6 or SC12 cable.

Some customers have found the longer SC12R-6 particularly useful for DSP4 Heads Up Display applications.

 


Specifications

Connectors One 9-pin pin (male), two 9-pin socket (female)
Operating Temperature Range -65° to +150°C
Length 182.9 cm (72.0 in.)
Weight 227 g (8 oz)

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR10X (retired)
CR200X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR3000 (retired)
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR800 (retired)
CR800 (retired)
CR850 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Peripherals

The SC12R6 can be used with many of our standard communication peripherals including our COM220, COM320, CR1000KD, MD485, RF401-series, RF450, TX312, SC32B, RF500M, ST-21, SC105, SC-USB, NL100, SC932A, and SDS122. Retired products that are compatible with this cable include the SC532A, DSP4, COM200, COM210, COM310, COM300, CR10KD, SDC99, COM100, CSM1, SAT ARGOS, ST-20, SAT HDR GOES, DC112, DC1765, SC232, SC32A, SC532, SC932, SC95A, SM16, SM192, SM64, SM232A, SM716, and VS1.

Data Logger Considerations

The SC12R-6 is compatible with any data logger with a nine-pin CS I/O port.


Privacy Policy Update

We've updated our privacy policy.  Learn More