PC200W is a free starter software package designed for first-time users or users with simple data communication needs; it provides basic tools (clock set, program download, monitor data, retrieve data, etc.). PC200W supports direct connections between a PC and datalogger (no telecommunications or scheduled data-collection support).

After a program is created with our Short Cut Program Generator (included), PC200W is typically used to download the program to the datalogger.


Read More

Benefits and Features

  • Provides basic tools (clock set, program download, monitor measurements, retrieve data, terminal emulation, etc.)
  • Compatible with most Campbell Scientific data loggers
  • Communicates with mixed-array, table, and PakBus data logger operating systems
  • Can be downloaded free of charge; see Downloads section or Download Now button on web page

Images


Detailed Description

PC200W was designed expressly for the beginning user so a manual is not necessary. Context-sensitive help is available throughout the program by pressing F1.

Communications

PC200W allows you to:

  • Send programs to the data loggers
  • Collect data
  • Set the data logger clock
  • Access a terminal emulation mode

Note: PC200W only supports direct communications. Telemetry requires either LoggerNet or PC400 Datalogger Support Software. LoggerNet also supports scheduled data collection. For more information, contact Campbell Scientific.

Data Processing and Display

PC200W collects and stores data in comma-separated files on your PC. It includes View Pro, which displays data files in tabular or graphical form. For mixed-array data loggers, a simple Split program is included that separates arrays in a data file into separate files.

CardConvert

CardConvert is used to convert and save binary data from a PC Card, CompactFlash card, or microSD card. Our CR5000 and CR9000X dataloggers store data on a PC Card via their on-board PCMCIA card slot, and store data on a CompactFlash card via the CF1 CompactFlash Adapter. Our CR1000 and CR3000 dataloggers store data on a CompactFlash card via the CFM100 CompactFlash Module or NL116 Ethernet Interface and CompactFlash Module. Our CR6 and CR1000X dataloggers store data on a microSD card.

Data Logger Programming

PC200W includes Short Cut for creating simple data logger programs. Programs created with the CRBasic Editor or Edlog can be sent to the data logger using PC200W.

  • Download Short Cut Program Generator at no charge. 
  • CRBasic is a program editor included in LoggerNet and PC400 Datalogger Support Software.
  • Edlog is a program editor included in LoggerNet and PC400 Datalogger Support Software.

License for Use

PC200W is copyrighted software. Campbell Scientific distributes this software free of charge to enable users to work with Campbell Scientific data acquisition equipment. PC200W may be freely copied; however, neither PC200W nor any of its files may be sold or included in any other software or altered in any way without prior permission from Campbell Scientific, Inc.

Limited Warranty

Campbell Scientific, Inc., does not warrant that the software will meet licensee’s requirements or that the software or documentation are error free or that the operation of the software will be uninterrupted. Campbell Scientific, Inc., is not responsible for problems caused by computer hardware, computer operating systems or the use of Campbell Scientific, Inc.’s software with non-Campbell Scientific, Inc. software.

All warranties of merchantability and fitness for a particular purpose are disclaimed and excluded. Campbell Scientific, Inc., shall not in any case be liable for special, incidental, consequential, indirect, or other similar damages even if Campbell Scientific, Inc., has been advised of the possibility of such damages.

Campbell Scientific, Inc., is not responsible for any costs incurred as result of lost profits or revenue, loss of use of the software, loss of data, cost of re-creating lost data, the cost of any substitute program, claims by any party other than licensee, or for other similar costs.

Licensee’s sole and exclusive remedy is set forth in this limited warranty. Campbell Scientific, Inc.’s aggregate liability arising from, or relating to, this agreement or the software or documentation (regardless of the form of action; e.g., contract, tort, computer malpractice, fraud and/or otherwise) is limited to the purchase price paid by the licensee.


Specifications

Current Version 4.5
Operating System Windows 10, 8, or 7
Purchased Separately Free download
Software Level Entry
Communications Supported Direct connect
Scheduled Data Collection Supported No
Data Display Supported Numeric, simple, line graph

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired) The 21X requires three PROMs; two PROM 21X Microloggers are not compatible.
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired)
CR200X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired)
CR300
CR3000 (retired)
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired)
CR6
CR800 (retired)
CR850 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Computer Requirements

Recommended computer operating systems—Windows 10

Communications

Only direct connection between the PC and data logger is supported (telecommunications are not supported and neither is scheduled data collection). PC200W supports PC cards, CompactFlash cards, and microSD cards.


Documents



Downloads

PC200W Spanish v.4.1 (816 KB) 17-02-2012

Spanish language files for PC200W 4.1.

Short Cut v.4.6 (32.6 MB) 02-10-2024

Short Cut creates simple programs for our CR200-series, CR300-series, CR510, CR500, CR10(X), 21X, CR23X, CR6, CR800, CR1000(X), CR1000Xe, CR3000, CR5000, CR9000X and GRANITE dataloggers. Both mixed array and table data operating systems are supported. Short Cut also supports our ET106, ET107 and MetData1 weather stations. The newest version includes the latest sensor files.

View Revision History

Device Configuration Utility v.2.30 (46.9 MB) 02-10-2024

A software utility used to download operating systems and set up Campbell Scientific hardware. Also will update PakBus Graph and the Network Planner if they have been installed previously by another Campbell Scientific software package.

Supported Operating Systems:

Windows 11 or 10 (Both 32 and 64 bit)

View Revision History

Frequently Asked Questions

Number of FAQs related to PC200: 29

Expand AllCollapse All

  1. Units cannot be displayed in the Monitor Data tab of PC200W.  When data is collected using PC200W, the units, if known, are contained in the header of the data file. They can be displayed in View by selecting the View | Show Full Header menu item.

  2. Yes. To clear data tables, follow these steps:

    1. Connect to the data logger, and open the Station Status window.
    2. On the Table Fill Times tab, select the tables to clear.
    3. Press the Reset Tables button.
  3. The latest version of PC200W can be downloaded free-of-charge from the Downloads area of the PC200W product page. 

  4. After a multiplexer has been added in Short Cut (SCWin), all the sensors that can be added to the multiplexer are listed in the Available Sensors and Devices tree. Short Cut only allows two different sensors to be added to a multiplexer if they are both measured using the same type of measurement (that is, single-ended, differential, half bridge, 3-wire half bridge, etc.). After a sensor is added to the multiplexer, the Available Sensors and Devices tree lists only those sensors that require the same type of measurement as the first sensor added.

  5. Data records are collected (downloaded from the data logger to the PC) from the PC200W Collect Data tab. The records can be viewed and printed by selecting View from the PC200W toolbar or the Tools menu.

    • PC208W is a retired data logger support software package. It was replaced by LoggerNet in 2004.