Services Available |
---|
The CS615 Water Content Reflectometer measures the volumetric water content of porous media using time-domain measurement methods. The reflectometer connects directly to the single-ended analog input of a Campbell Scientific CR510, CR10(X), or CR23X, or to the pulse count channel of a CR510, CR10(X), 21X, CR23X, or CR7 datalogger. The data logger period or frequency output can be converted to volumetric water content using calibration values.
The "-L" on a product model indicates that the cable length is specified at the time of order.
The CS615 was replaced by the CS616, which offers a faster, less noise emissive measurement that meets CE standards.
Accuracy |
|
Power | 70 mA (@ 12 Vdc) |
Rod Spacing | 3.2 cm (1.26 in.) |
Rod Diameter | 3.2 mm (0.126 in.) |
Rod Length | 30.0 cm (11.81 in.) |
Weight | 280 g (0.617 lb) |
Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.