Digital Cameras / CC5MPXWD
RETIRED ›
This product is no longer available and has been replaced by: CCFC. Some accessories, replacement parts, or services may still be available.
CC5MPXWD Digital Camera with Window Defroster
Services Available
Repair No
Free Support Yes

Overview

The CC5MPXWD is similar to the CC5MPX, except it includes an internal defroster that prevents and removes light frost and icing from the camera's window. This high-resolution digital camera produces JPG images with a resolution of up to 5 megapixels, and shoots videos with a resolution of up to 720P. It has an integrated environmentally sealed enclosure that protects the camera from moisture and high humidity. An SD memory card for image storage is available as an option.


Read More

Benefits and Features

  • Compatible with PakBus data loggers
  • Can be controlled by internal timer or by external controls: motion detector, web page, data logger
  • Designed to work in harsh environments, this camera operates at temperatures as low as -40°C and as high as 60°C

Images


Detailed Description

The CC5MPXWD can function as a stand-alone camera or can be connected to a Campbell Scientific datalogger or another PakBus device. It has several options for image acquisition and storage. You can take still images or videos based on an internal timer, motion detection, or a trigger from an external PakBus device (such as a datalogger). The images or videos can then be stored on an SD card, saved in a datalogger’s memory, sent to a PC via email, or transmitted to an FTP server.

The CC5MPXWD's defroster consists of an aluminum ring with a resistive type heating element. Springs are used to press the defroster against the camera's window.

The defroster turns on when the internal temperature is below a specified value and not in the low powered state. You can also specify the number of minutes before a self-timed schedule that the defroster will turn on.

With extreme icing or riming conditions and low temperatures, the window defroster may not be able to clear the window due to the power constraints of the defroster.


Specifications

Heating Element Resistance 18 Ω
Operating Power 9 to 16 Vdc
Operating at voltages greater than 16 Vdc can damage the camera.
Operating Temperature Range -40° to +60°C
Clock Accuracy ±2 minutes per year (-40° to +60°C)
Photo or Video Capture Triggers Two independent self timers, external trigger, motion detection, web page control
Programmable Still Image Resolutions
  • 2592 x 1944 (JPEG)
  • 1280 x 960 (JPEG)
  • 1280 x 720 (JPEG)
  • 640 x 480 (JPEG)
  • 640 x 352 (JPEG)
  • 320 x 240 (JPEG)
  • 320 x 176 (JPEG)
Video Capable of up to 720P for the following:
  • 1280 x 720 (MPEG4)
  • 640 x 480 (MJPEG)
  • 320 x 240 (MPEG4)
Communication Interfaces RS-232 port; RS-485 port; Ethernet 10/100
Communications Protocols PakBus, FTP, email, web page interface via web browser
Maximum Baud Rate 115.2 kbps (for RS-232 and RS-485 only)
Window Defroster Yes
Wi-Fi Capable No
Low-Light Capability Not designed for low-light conditions.
NDVI Capability No
Diameter 9.3 cm (3.7 in.)
Length 22 cm (8.7 in.)
Weight 1.06 kg (2.34 lb)

Communication Switched Power Output

Maximum Output Current 750 mA

Current Drain (camera only)

Maximum 250 mA (at 12 Vdc)
Quiescent ≤1 mA (off power mode)

Current Drain (with defroster on)

Typical 1.0 A (@ 12 Vdc)
Maximum 1.2 A (@ 16 Vdc)

Lens

Mount C-type
IRIS DC compatible
Standard Lens 4 to 12 mm, 27° to 80° FOV

External Input Signal

Logic Low Level 0.65 Vdc (-20 Vdc absolute minimum)
Logic High Level > 2.0 Vdc (+20 Vdc absolute maximum)
Minimum Pulse Width 10 ms

Memory Card Interface

Type Secure Digital (SD)
File System FAT32
File Type JPEG (image), AVI (video)
Size 16 GB or less

Photo Capture Time

-NOTE- Time is from wake-up to start of capture.
Fully On < 1 s (5 MP images take longer.)
Partially On 10 s
Deep Sleep 15 s
Off State 90 s

Compatibility

Please note: The following shows notable compatibility information. It is not a comprehensive list of all compatible products.

Dataloggers

Product Compatible Note
21X (retired)
CR10 (retired)
CR1000 (retired)
CR1000X
CR10X (retired) The CR10X must be the -2M version and must use the PakBus operating system.
CR200X (retired)
CR211X (retired)
CR216X (retired)
CR23X (retired) The CR23X must be the -2M version and must use the PakBus operating system.
CR300
CR3000 (retired)
CR310
CR500 (retired)
CR5000 (retired)
CR510 (retired) The CR510 must be the -2M version and must use the PakBus operating system.
CR800 (retired)
CR850 (retired)
CR9000 (retired)
CR9000X (retired)

Additional Compatibility Information

Mounting

The 18549 Camera Mounting Kit is used to mount the CC5MPXWD camera to a CM202, CM204, or CM206 crossarm. The crossarm then attaches to a tripod, tower, or user-supplied pole (1.0-in. to 2.1-in. outer diameter). The bracket’s design facilitates the aiming of the camera.

Data Logger Considerations

The CC5MPXWD is compatible with any PakBus data logger that has 2 MB or greater of on-board memory. The data logger must have a current operating system.

Connections

The CC5MPXCBL1 Power and I/O Cable connects the camera to:

  • Power supply
  • COM port of a CR800, CR850, CR1000, or CR3000 datalogger
  • MD485 Multidrop Modem (for connecting more than one camera to a data logger or if long cable lengths are required)
  • PC (for configuring camera via the Device Configuration utility; also requires the DB9M-TERM interface that is shipped with the camera)

An Ethernet cable is required to configure the camera. Typically, the CC5MPXCBL2 Environmental Cable is used. The Ethernet cable connects the camera to a network router, cellular modem, or laptop. With this connection, the user can access a web interface that:

  • Allows adjustment of camera targeting/focusing
  • Supports camera configuration
  • Displays camera information, system status, date and time


Downloads

CC5MPX OS v.1.25.1 (13.8 MB) 24-06-2019

Current CC5MPX Camera Operating System.

Note: Do not extract the firmware update file “CC5MPX_FW_1_25_1.tar.gz”.This compressed file gets sent to the CC5MPX as is.

View Revision History

CC5MPX PIC OS v.2.0 (18 Kb) 18-11-2014

Current firmware for the CC5MPX Peripheral Interface Controller (PIC)

Note: In order for the CC5MPX to accept the PIC firmware the CC5MPX OS 1.23 or higher must be running in the camera. Retrieve the CC5MPX_PIC_UPDATE_V2_JUNE_17_2014.hex.gz firmware from the .zip file. Do not extract the firmware update file "CC5MPX_PIC_UPDATE_V2_JUNE_17_2014.hex.gz". This compressed file must be sent to the CC5MPX as a “.gz” file.  Details related to updating firmware can be found in the CC5MPX manual.


Frequently Asked Questions

Number of FAQs related to CC5MPXWD: 14

Expand AllCollapse All

  1. The idle timeout on the FTP server is set for 15 minutes. If the server doesn’t see any communication from the client within 15 minutes, it will close the connection.
  2. The Device Configuration Utility provides an easy method for resetting the device to its factory defaults. Connect and click Factory Defaults, and then apply them.

  3. This is done by sending images via PakBus to a Campbell Scientific data logger with a cellular modem telemetry option. The cable that is used is the CC5MPXCBL1-L Power and I/O Cable, which provides power from the data logger, as well as an RS-232 or RS-485 connection.

  4. The CC5MPXCBL2-L is an environmentally sealed Ethernet (RJ45) cable that provides access to the network functionalities of the CC5MPX family of cameras. This cable is used with a camera to do the following: send emails, transfer images via FTP (accessing either a web server or an optional internal SD memory card), synchronize with a network time server, or gain access to the camera’s configuration web page. The CC5MPXCBL2-L can also be used to connect the CC5MPX directly to an Ethernet port, such as a cellular modem or wireless router. In addition, Campbell Scientific recommends using this cable if the CC5MPX is mounted on a tall tower or in a location that is not easily accessible.

    Note: The camera’s internally served configuration web page is the only way to view the real-time streaming video that is used to manually zoom and focus the camera.

  5. This may be possible. Contact Campbell Scientific for assistance with this.

  6. The CC5MPX uses a standard C-Type mount lens. If a lens fits within the lens tube barrel, or if the camera will be used in an environment where the front lens tube barrel is unnecessary, other lenses, such as a zoom or fisheye may be used.

    Note: Use of an alternate lens may void the product warranty.

  7. This depends. Typically, most camera applications require an environmentally sealed cable, such as the CC5MPXCBL2-L, rather than a generic Ethernet cable. However, for indoor or temporary applications where the cable will not be exposed to weather elements, use a standard 10Base-T CAT5e Ethernet cable.

  8. Although the CC5MPX’s enclosure is weather resistant, it is not designed for underwater use. However, if a watertight enclosure is rated suitable for saltwater environments, and there is physical space for the CC5MPX within the enclosure, then the camera will function as designed.

    Note: Campbell Scientific does not offer any watertight enclosures rated suitable for saltwater environments.

  9. Although the CC5MPX can’t stream live video directly into RTMC, it can transfer images via FTP to a webserver that RTMC has access to. Depending on the update frequency, the images can be updated at near real-time, as long as the CC5MPX and the webserver are configured to allow this.

    Embedding a live stream from the CC5MPX into an existing web page can be done using the Real Time Streaming Protocol (RTSP). Contact Campbell Scientific for details.

  10. Yes. This is the recommended method to access the CC5MPX’s memory card. On most Windows machines, this is easily done by typing ftp://192.168.1.90:85 into Windows Explorer, where “192.168.1.90” is the IP address of the camera and “:85” is the port used for FTP access.


Privacy Policy Update