CS215-MET2 Temperature and Relative Humidity Kit for MET200
Services Available

Overview

The CS215-MET2 is a temperature and relative humidity kit with a mil-spec connector on the cable for attaching to a MET200 and a RAD-06 Radiation shield.  It uses a Swiss-made digital humidity and temperature element that makes accurate and stable measurements. Cable length is 2 meters.

This sensor is only compatible with the MET200 system.


Read More

Images


Detailed Description

For this version of the CS215 Temperature and RH Probe, the cable has, instead of pigtails, a mil-spec connector for attachment to the MET200. Cable length is 2 meters.

The CS215-MET2 uses the Sensirion SHT75, a combined relative humidity and temperature element, to provide accurate, stable measurements. The Sensirion SHT75 element is field-replaceable, eliminating the downtime typically required for the recalibration process. 

The CS215-MET2 includes a 6 plate solar radiation shield. 


Specifications

  • Sensing Element: Sensirion SHT75
  • Communication Standard: SDI-12 V1.3 (responds to a subset of commands)
  • Supply Voltage: 6 to 16 Vdc (typically powered by datalogger’s 12 V supply)
  • Typical Current Drain: 120 μA (quiescent); 1.7 mA (measurement; takes 0.7 s)
  • EMC Compliance: Tested and conforms to IEC61326:2002
  • Operating Temperature: -40° to +70°C
  • Length including strain relief: 18.0 cm (7.1")
  • Diameter at sensor tip: 1.2 cm (0.5")
  • Diameter at cable end: 1.8 cm (0.7")
  • Weight w/10 ft cable 150 g (5.3 oz)

Relative Humidity

  • Measurement Range: 0 to 100% RH
    (-20° to +60°C)
  • Output Resolution: 0.03% RH
  • Accuracy (at 25°C):
    ±2% (10% to 90% range),
    ±4% (0% to 100% range)
  • Short Term Hysteresis: < 1% RH
  • Temperature Dependence: better than ±2% (-20° to 60°C)
  • Stability (Typical): ±1.0% per year
  • Response Time with Filter: < 20 s (63%
    response time in still air)
  • Calibration Traceability: NIST and NPL standards

Temperature

  • Measurement Range: -40° to +70°C
  • Output Resolution: 0.01°C
  • Accuracy:
    ±0.3°C at 25°C;
    ±0.4°C (+5° to +40°C);
    ±0.9°C (-40° to +70°C)
  • Response Time w/Filter: < 120 s (63% response time in air moving at 1 m s-1)

Compatibility

The CS215-MET2 is only compatible with the MET200 system.